There are two types of internal batteries commonly used in energy storage system batteries (Read: what is an energy storage system?) : Lifepo4 battery and lead-acid battery. Most of the batteries used in the early days were mainly lead-acid batteries. With the continuous improvement of technology and the increasing awareness of environmental protection, gradually replaced by Lifepo4 battery.
The lithium iron phosphate battery is a lithium ion battery using LiFePO4 as the positive electrode material and carbon as the negative electrode material. The rated voltage of the single battery is 3.2V, and the charge cut-off voltage is 3.6V~3.65V.
MANLY LiFePO4 Energy Storage System Battery
MANLY LiFePO4 battery has a series of unique advantages such as high working voltage, high energy density, long cycle life, green environmental protection, etc., and supports stepless expansion, and can be used for large-scale electrical energy storage after forming an energy storage system. Lifepo4 battery energy storage system consists of LiFePO4 battery pack, Battery Management System (BMS), converter device (rectifier, inverter), central monitoring system, transformer, etc.
In the charging stage, the intermittent power supply or the power grid charges the energy storage system, and the alternating current is rectified into direct current through the rectifier to charge the energy storage battery module and store energy; in the discharge stage, the energy storage system discharges to the power grid or the load, and the energy storage battery module The DC power of the inverter is converted into AC power through the inverter, and the inverter output is controlled by the central monitoring system, which can provide stable power output to the grid or load.
Features of MANLY LiFePO4 Battery:
Market Applications of Energy Storage Systems Battery
MANLY LiFePO4 battery has a series of unique advantages such as high working voltage, high energy density, long cycle life, low self-discharge rate, no memory effect, green environmental protection, etc., and supports stepless expansion, suitable for large-scale electric energy storage, power generation in renewable energy Safe grid connection of station power generation, off-grid power consumption, grid peak regulation, distributed power station, UPS power supply, emergency power supply system, etc.
Model No. |
Nominal Voltage(V) |
Nominal Capacity(AH) |
Charging Current(A) |
Discharge Current(A) |
Communication Protocol |
Bluetooth |
Dimension(mm) |
MF4850 |
51.2 | 50 | 50 | 1-100 | Optional (A below) | Optional (B below) | 483*434*133 |
MF48100 |
51.2 | 100 | 100 | 1-200 | Optional (A below) | Optional (B below) |
483*438*178 |
MF48120 |
51.2 | 100 | 100 | 1-200 | Optional (A below) | Optional (B below) | 495*455*210 |
MF4850E |
48.0 | 50 | 50 | 1-100 | Optional (A below) | Optional (B below) |
483*434*133 |
MF48100E |
48.0 | 100 | 100 | 1-200 | Optional (A below) | Optional (B below) |
483*438*178 |
MF48120E |
48.0 | 100 | 100 | 1-200 | Optional (A below) | Optional (B below) |
495*455*210 |